{"product_id":"cl1-cl4-gsm-relay-controller-sms-call-remote-control-power-switch-home-automation-for-gates-electric-door-opener-lock-pump-motor","title":"CL1 CL4 GSM Relay Controller SMS Call Remote Control Power Switch Home Automation for Gates Electric Door Opener Lock Pump Motor","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eApp control\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003ecommunicate via SMS network\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eKONLEN\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCall control\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eOnly available for first relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eGSM network\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e2G\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eMaterial of outer shell\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAluminum alloy\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel 1\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCL1-GSM with one relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel 2\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCL2-GSM with two relays\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel 3\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCL4-GSM with 4 relays\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCL1 CL2 CL4 GSM\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePowered\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eby 12V 1A power adapter\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eRelay output\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e10A\/30VDC, 10A\/250VAC\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eRemote control\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eby SMS, SMS or App\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eVoltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e110-240V\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_dynamic\"\u003e\u003ckse:widget data-widget-type=\"customText\" id=\"1005000001298845\" type=\"relation\"\u003e\u003c\/kse:widget\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cp\u003eThere are many places, such as remote base station,PBX Switchboard, Water Pump, Router, Server, Gate, Power distribution room, brewery, greenhouse etc.,where are no WIFI coverage. If you want to control the equipments on\/off in these places remotely, the GSM relay controllers will be your best option. You can control the devices anywhere anytime via GSM network.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align:left\" align=\"left\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H51e32da0db344a9abecc2d223ca20af3B.png\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThere are three model: CL1-GSM with one relay output, CL2-GSM with two relay outputs, CL4-GSM with 4 relay outputs, each model with white antennat and black antenna for option. If need install the relay controllers in some place without good gsm network signal, suggest to choose the black extended antenna, users can move the black antenna to other places with better gsm signal.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align:left\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px\"\u003e                                                         Application\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Hcd4360f8b1a740128a84dc9e28cb43f7g.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px\"\u003eTips\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e1. Remote Control, no distance limitation\u003c\/p\u003e\n\u003cp\u003e1. SMS control: All the people who know SMS command and password can send SMS text to control the device.\u003c\/p\u003e\n\u003cp\u003e2. Free Call Control: When the device detects the ring call, the relay 1 will change status, so call control is free of charge. But the call control is only available for first relay ouput.\u003c\/p\u003e\n\u003cp\u003e3. App control: Combine the SMS\/Call commands to be APP icons, which is easier to operate. So the APP still communicates with relay controllers via SMS text and phone call of 2G GSM network.\u003c\/p\u003e\n\u003cp\u003e4. Each relay output load: 10A\/30VDC, 10A\/250VAC\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H463875983cfe499395c1392545a917d14.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align:left\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px\"\u003eSMS Control Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll the people who know SMS command and password can send SMS text to control the device.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align:left\" align=\"left\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px\"\u003eMode 1. SMS on\/off command\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align:left\" align=\"left\"\u003e\u003cspan style=\"font-size:16px\"\u003eON command: SN + PASSWORD + ON ,  can change the relay status to be all ON.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align:left\" align=\"left\"\u003e\u003cspan style=\"font-size:16px\"\u003eOFF command: SN+ PASSWORD + OFF,  can change the relay status to be all OFF.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Ha1ae064aa3f04079b0a49860ebe049d42.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cstrong\u003eMode 2: COM Command\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003eCOM command can control each path of relay status separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003eSMS format: SN + PASSWORD + COM + Relay status code  N or F ( N stands for ON, F stands for Off, X stand for state no change ).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003eTake CL4-GSM as example:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003eCL4 has 4 relay outputs. If you want the relay 1 ON, relay 2 ON, relay 3 OFF, relay 4 ON, the password is 0000, edit SMS text: SN0000COMNNFN\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H510266dbc04e4239b638fe362d0830c3C.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cstrong\u003eMode 3: T Command: Inching the relay state in short time. \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe command is suitable to control electric Door Gate \/ Garage door.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eSMS Text: SN + password +T + inching time (0 to 9)\u003c\/p\u003e\n\u003cp\u003e0 stands for 0.5 second, 1-9 stands for 1 to 9 seconds\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eFor example: a. Send SMS text: SN0000T2, start to inch the relay.\u003c\/p\u003e\n\u003cp\u003eon-----off 2 seconds-----on;\u003c\/p\u003e\n\u003cp\u003eoff-----on 2 seconds------off\u003c\/p\u003e\n\u003cp\u003eIf the original relay status is ON, it will change to be OFF and held on the OFF state for 2 seconds, then recover to be ON automatically.\u003c\/p\u003e\n\u003cp\u003eIf the original relay status is OFF, it will change to be ON and held on the ON state for 2 seconds, then recover to be OFF automatically.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor CL2 and CL4, the SMS command need add state control code C or X of each relay, C stand for excuting the relay inching command, X stand for relay state no change\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H9b84f3f1a35243109a1489f625bd235b7.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:18px\"\u003eMode 4: L Command\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLong-time Inching relay switch: Timing control from 001 to 240 Minutes via L Commands. With the function, users can timed-control pond aerator, water pump, routers, server, DC\/AC motor and other electrical equipments by SMS\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eSMS Text: SN + password + L + inching time ( 001 to 240 minutes)\u003c\/p\u003e\n\u003cp\u003eFor example. a. Send SMS: SN0000L060\u003c\/p\u003e\n\u003cp\u003eon-----off 60 minutes-----on;\u003c\/p\u003e\n\u003cp\u003eoff-----on 60 minutes-----off\u003c\/p\u003e\n\u003cp\u003eIf the original relay status is ON, it will change to be OFF and held on the OFF state for 60 minutes, then recover to be ON automatically.\u003c\/p\u003e\n\u003cp\u003eIf the original relay status is OFF, it will change to be ON and held on the ON state for 60 minutes, then recover to be OFF automatically.\u003c\/p\u003e\n\u003cp\u003eb. Send SMS: SN0000L030 (on-----off 30 minutes-----on; off-----on 30 minutes-----off)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: For CL2 and CL4, the SMS command need add state control code C or X of each relay, C stand for excuting the relay inching timing command, X stand for relay state no change.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H9612d9b4a43d4c0290b8facf60bb3b992.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H30444a3ffb9c49b4856c7c16fe0c44b2g.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cstrong\u003eMode 5: Set master number of call control via SMS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cstrong\u003eMode 6: Send SMS text: SN + Password + CHECK, can reply the state of each relay.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cstrong\u003eMode 7: SMS text change password.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Hcd1b3a64f3b743af87b5822fac563d75R.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px\"\u003eCall Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:14px\"\u003eWhen the device detects the ring call, the relay 1 will change status, so call control is free of charge. But the call control is only available for first relay ouput, invalid to relay 2, relay 3, relay 4.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H521341ce4ce14aaa9820a2aeada8a76a4.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H90693570aa234d658dfccb0e30bc6f37G.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:18px\"\u003eAPP control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:14px\"\u003eCombine the SMS\/Call control commands to be APP icons, which is easier to operate. So the APP still communicates with relay controllers via SMS text and phone call of 2G GSM network.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H31eb66749c4b41b1a4ac9fc63cd0eeb1J.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H6cb343dd5b3749ec89853ebeb12ca83c7.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style='font-family:\"Open Sans\", Arial, Helvetica, sans-serif, Heiti;font-size:14px;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0);background-color:rgb(255, 255, 255);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box' align=\"start\"\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cstrong\u003eWring connection of CL1-GSM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e1. Relay output load: 10A\/30VDC, 10A\/250VAC\u003c\/p\u003e\n\u003cdiv style='font-family:\"Open Sans\", Arial, Helvetica, sans-serif, Heiti;font-size:14px;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0);background-color:rgb(255, 255, 255);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box' align=\"start\"\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003e2. DC motor or other devices (power below 80W)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003e3. AC bulb\/LED\/other devices (power below 200W)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003eIf you want to connect with high-power AC motor equipment ( more than 400W), please add AC contactor additionally by yourself.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003e4. Tips: Circuit wiring requires proffessional operation, please handle it carefully.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Hf1bc5d69c62d4d39954e2b02b5eed4dfp.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H4f7bd850c5f2403c8443a2aa0ceefe9b8.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Haea4d829b45445d78f3e6fde4422b6c15.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Ha5f86e0225b14b0b95bdd89c886aeeb91.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style='font-family:\"Open Sans\", Arial, Helvetica, sans-serif, Heiti;font-size:14px;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0);background-color:rgb(255, 255, 255);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box' align=\"start\"\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cstrong\u003eWring connection of CL2-GSM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e1. Each relay output load: 10A\/30VDC, 10A\/250VAC\u003c\/p\u003e\n\u003cdiv style='font-family:\"Open Sans\", Arial, Helvetica, sans-serif, Heiti;font-size:14px;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0);background-color:rgb(255, 255, 255);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box' align=\"start\"\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003e2. DC motor or other devices (power below 80W)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003e3. AC bulb\/LED\/other devices (power below 200W)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003eIf you want to connect with high-power AC motor equipment ( more than 400W), please add AC contactor additionally by yourself.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003e4. Tips: Circuit wiring requires proffessional operation, please handle it carefully.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Hccc90198669a4e79aad37b93b12cd564l.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H8bb44ba0439e4d4b952acb0e6f5559faW.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H208f637af36843c097c6381dd91b3cc0C.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H5077b7df861e4fa2a283aa49e785f03dc.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style='font-family:\"Open Sans\", Arial, Helvetica, sans-serif, Heiti;font-size:14px;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0);background-color:rgb(255, 255, 255);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box' align=\"start\"\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cstrong\u003eWring connection of CL4-GSM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cp\u003e1. Relay output load: 10A\/30VDC, 10A\/250VAC\u003c\/p\u003e\n\u003cdiv style='font-family:\"Open Sans\", Arial, Helvetica, sans-serif, Heiti;font-size:14px;font-weight:400;letter-spacing:normal;text-align:start;white-space:normal;color:rgb(0, 0, 0);background-color:rgb(255, 255, 255);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box' align=\"start\"\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003e2. DC motor or other devices (power below 80W)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003e3. AC bulb\/LED\/other devices (power below 200W)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003eIf you want to connect with high-power AC motor equipment ( more than 400W), please add AC contactor additionally by yourself.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:content-box\"\u003e\u003cspan style=\"font-size:16px\"\u003e4. Tips: Circuit wiring requires proffessional operation, please handle it carefully.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Hd55f81c816fb46bc8753071925768202A.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Hd7259edab1264713a140def80107c5ff3.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/H98530e2e663a466b801f43b02325be753.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"DOLLAR CHARM","offers":[{"title":"CL2 Black Antenna","offer_id":49331103858926,"sku":"14:175#CL2 Black Antenna","price":127.99,"currency_code":"USD","in_stock":true},{"title":"CL2 White Antenna","offer_id":49331103891694,"sku":"14:173#CL2 White Antenna","price":115.99,"currency_code":"USD","in_stock":true},{"title":"CL1 Black Antenna","offer_id":49331103924462,"sku":"14:29#CL1 Black Antenna","price":119.99,"currency_code":"USD","in_stock":true},{"title":"CL1 White Antenna","offer_id":49331103957230,"sku":"14:193#CL1 White Antenna","price":106.99,"currency_code":"USD","in_stock":true},{"title":"CL4 Black Antenna","offer_id":49331103989998,"sku":"14:691#CL4 Black Antenna","price":158.99,"currency_code":"USD","in_stock":true},{"title":"CL4 White Antenna","offer_id":49331104022766,"sku":"14:366#CL4 White Antenna","price":147.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/7065\/9566\/files\/H85009053e82a4d298939c9bcc405b075i.webp?v=1785429802","url":"https:\/\/dollarcharm.com\/products\/cl1-cl4-gsm-relay-controller-sms-call-remote-control-power-switch-home-automation-for-gates-electric-door-opener-lock-pump-motor","provider":"DOLLAR CHARM","version":"1.0","type":"link"}